認知機能検査/評価プログラムによる認知機能スコア(総合点)とMMSE(Mini-Mental State Examination)の認知機能スコア(総合点)との相関性を評価し、当該プログラムの性能及び認知機能検査としての有用性を検証する |
|||
3 | |||
2021年03月26日 | |||
2021年04月06日 | |||
2021年02月15日 | |||
2021年07月31日 | |||
|
75 | ||
|
介入研究 | Interventional | |
Study Design |
|
単一群 | single arm study |
|
非盲検 | open(masking not used) | |
|
非対照 | uncontrolled control | |
|
単群比較 | single assignment | |
|
その他 | other | |
|
なし | ||
|
なし | ||
|
なし | ||
|
|||
|
なし | none | |
|
|
以下のすべての項目を満たすものを選択する。 1. 治験参加に対して本人による文書同意が得られた者。ただし、認知症の診断がなされている被験者については代諾者同意が得られた者とし、同意能力ありと判断された場合は本人同意も併せて取得する 2. 認知症の診断を受けていない者については、活動性の神経疾患又は精神病の既往及び合併のない者 |
The inclusion criteria on this study is as follows; 1. Participants who sign the consent document by their own decision. The consent can be obtained by proxies when the participants with dementia have substiantial impairments in their abilities to understand. If those with dementia seem to be able to comprehend the information provided, the consent needs to be obtained from both the participant and his/her proxy. 2. Participants without current or past diagnosis of neurological or mental diseases. |
|
以下のいずれかに該当するものを除外する。 1. 視線検出に影響を与える程度の眼科疾患等(例えば、斜視、白内障等により十分な視力が得られないもの、及び緑内障、糖尿病等による視野欠損のあるもの)を有していて、視線検出ができないと判断した者。視力矯正等目的で下記に該当する視力矯正器具を使用している者はそれらを使用せずに検査が実施できること 1) 十分な明度が得られず、色調の認識が困難なサングラス 2) 眼鏡フレームが極端に小さいか厚みが大きいもの 3) 強度近視((-6.25 diopter以上)等で視力補正レンズの屈折が大きく、アイ・トラッキングが困難なもの 4) 水晶体摘出術後の視力補正レンズ(+13 diopter程度)等で視力補正レンズの屈折が大きく、アイ・トラッキングが困難なもの 5) レンズの下部が近見用(凸レンズ)となっている二焦点レンズまたは多焦点レンズ 2. MMSEの実施が困難であることが明らかな運動障害を伴う神経疾患や難聴の者 3. 本治験登録の3ヶ月以内に本プログラムによる検査またはMMSEを実施した者 4. その他、治験責任医師等が本治験への参加を不適当と判断した者(例えば、眼球振盪、外傷等により視線データを適正に測定することができない者、及び姿勢を維持することが困難な者) 5. 他の臨床試験に参加中、又は本治験の検査実施時までに参加を予定している者 |
The exclusion criteria on this study is as follows; 1. Participants with ophthalmic diseases such as strabismus, cataract, glaucoma and diabetic retionopathy. These diseases have a possibility to affect the gaze detection and tracking system because of weakened eyesight and partial visual field defect. Participants are asked to take off their glasses prior to the eye-tracking calibration, if they're wearing the following types of glasses to correct visual acuity. 1) dark shades sunglasses which make it impossible for the eye-tracking system to capture a clear view of the eyes 2) glasses with small frame or thick frame 3) glasses with high lens power for myopia of -6.25 diopters or more 4) glasses of +13 diopters or more for people who had surgical removal of the crystalline lens 5) multifocal lens glasses whose lower section consists of convex lens of short focal length 2. Participants who can't complete MMSE because they have neurological diseases with movement disorders or difficulties in hearing 3. Participants who took the eye-tracking based cognitive assessment used in this study or MMSE within the past three months prior to the enrollment date 4. Participants who are considered not to be eligible for this study by the study responsible physician. For example, participants with eye movement or alignment abnormalities because of nystagmus or trauma. Also, participants who can't maintain sitting posture during cognitibe assessments are excluded. 5. Participants taking part in other stydies, or those are going to participate in other studies by when they take the eye-tracking based cognitive assessment used in this study |
|
|
20歳 以上 | 20age old over | |
|
上限なし | No limit | |
|
男性・女性 | Both | |
|
|||
|
臨床的に認知症と診断された被験者及びそれ以外の被験者(認知機能健常者及びMCI(Mild cognitive impairment:軽度認知障害)が疑われる被験者を含む) | cognitively healthy subjects and subjects with dementia or mild cognitive impairment (MCI) | |
|
|||
|
|||
|
あり | ||
|
全被験者に対して、MMSE及び治験機器による認知機能検査を実施する。 |
All subjects will be performed for cognitive function with MMSE and investigational device. |
|
|
|||
|
|||
|
治験機器による認知機能スコア(総合点)とMMSEによる認知機能スコア(総合点)との相関性 |
A correlation of total cognitive scores between the clinical trial equipment and MMSE |
|
|
|
医療機器 | ||
---|---|---|---|
|
未承認 | ||
|
|
|
疾病診断用プログラム |
|
未定 | ||
|
なし | ||
|
|
||
|
|
あり |
---|
|
||
---|---|---|
|
研究終了 |
Complete |
|
|
あり | |
---|---|---|
|
|
あり |
|
臨床試験賠償責任保険 | |
|
|
株式会社アイ・ブレインサイエンス |
---|---|
|
Ai-Brainsciecne Inc. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
なし | |
---|---|---|
|
||
|
|
大阪大学医学部附属病院 治験審査委員会 | Institutional Review Board of Osaka University Hospital |
---|---|---|
|
大阪府吹田市山田丘2番2号 | 2-2 Yamadaoka, Suita-shi, Osaka |
|
06-6210-8290 | |
|
jim-chiken@hp-crc.med.osaka-u.ac.jp | |
|
||
|
承認 |
|
|
---|---|
|
|
|
|
|
該当しない |
---|---|---|
|
該当しない | |
|
該当しない | |
|
該当しない |
|
無 | No |
---|---|---|
|
|
|
---|---|
|
|
|
|
設定されていません |
---|---|
|
設定されていません |