肺葉切除術におけるstaple-line reinforcementの安全性・有効性を検討する。 | |||
4 | |||
実施計画の公表日 | |||
|
2023年05月31日 | ||
|
48 | ||
|
介入研究 | Interventional | |
Study Design |
|
単一群 | single arm study |
|
非盲検 | open(masking not used) | |
|
非対照 | uncontrolled control | |
|
単群比較 | single assignment | |
|
治療 | treatment purpose | |
|
なし | ||
|
なし | ||
|
なし | ||
|
|
(1) 20歳以上の男女。 (2) 術前PSが0-1の患者。 (3) 原発性肺癌,転移性肺腫瘍が疑われる患者。 (4) 胸腔鏡下肺葉切除術(ロボット支援含む)を行う予定の患者。 (5) 本研究に対し、本人から文書による同意が得られた患者。 |
1. Patients over 20 years old 2. Patients with a preoper ative PS of 0-1 3. Patients suspected with lung cancer or metastatic lung cancer. 4. Patients scheduled to undergo thoracoscopic surgery including robotic surgery 5. Patients who consented to the study in writing. |
|
(1) 過去に開胸手術、胸腔鏡下手術を施行された患者。 (2) 研究責任医師または研究分担医師が対象として不適格と判断した患者。 (3) 術前CT検査で完全分葉の患者。 (4) 予定した肺切除の範囲が2葉以上の患者。 |
(1) Patients who have undergone thoracotomy or thoracoscopic surgery in the past. (2) Patients whom the doctor judged unsuitable as the subject (3) Patient with complete Interlobar fissures of the lung on preoperative CT scan. (4) Patients with pulmonary resection range of 2 or more lobes. |
|
|
20歳 以上 | 20age old over | |
|
上限なし | No limit | |
|
男性・女性 | Both | |
|
症例ごとの中止基準 (1) 研究対象者から疾病等のためまたはそれ以外の理由により治療中止の申し出があった場合。 (2) 研究責任医師または研究分担医師の判断(ステイプルの使用が困難な場合、肺の脆弱性が著しく、術中高度の肺損傷を伴う場合等)。 (3) プロトコル治療中の死亡 (4) 術中に以下の状況となった場合には、プロトコル治療を中止する。 ・開胸手術に移行した ・肺切除の範囲が2葉以上へ変更となった ・胸腔内に高度な癒着を伴い研究責任医師または研究分担医師が安全に胸腔鏡手術ができないと判 断した ・術中所見により、完全分葉と判明した 研究の中止基準 (1) 予期できない重篤な有害事象・不具合の発生 (2) 予期できる重篤な有害事象・不具合の発生件数、発生頻度、発生条件等の発生傾向がインタビュ ーフォーム・添付文書から予測できないことを示す情報 (3) 重篤な疾病等のうち因果関係がないと判断されていたが、その後発生数、発生頻度、発生条件等 の発生傾向から因果関係が否定できないと判断される情報 |
||
|
肺癌 | Lung Cancer | |
|
|||
|
肺癌 | Lung cancer | |
|
あり | ||
|
胸腔鏡下肺葉切除術(ロボット支援含む)を行う予定の患者を対象とする。プロトコル治療は同意取得 から4週間以内に実施する。選択基準に当てはまる症例に対して術中の葉間切離(上下葉間、上中葉間 、中下葉間のいずれか)にstaple-line補強材を併用した自動縫合器を使用する。上下葉間、上中葉間 、中下葉間の3か所の切除面は補強材を併用し自動縫合器の使用にあたってそれぞれ差がない。術中の ウォーターシーリングテストにおいて加圧量5cmH₂O、10cmH₂O、15cmH₂O、20cmH₂Oで評価を行う。それぞれの圧でステイプラー断端のエアリークの発生の有無と発生部位を評価する。評価の後にエアリークが発生した場合には修復を行い、手術終了とする。修復後はエアリークの持続がないかの確認のみを行う。エアリーク持続期間、胸腔ドレーン留置期間、術後30日以内の呼吸器合併症の有無を確認して観察終了となる。 |
Patients scheduled for thoracoscopic lobectomy (including robotic-assisted surgery) are eligible. Protocol treatment will be performed after consent is obtained. For patients who meet the selection criteria, the procedure will be performed within 4 weeks after intraoperative lobectomy (upper and lower lobes, upper and middle lobes, upper and lower lobes). An automatic suture device with staple line reinforcement will be used in interlobar fissures. There is no difference in the use of automatic sutures device with reinforcement between any of the interlobar fissures. In the water seal test, evaluations were performed at applied pressures of 5 cmH2O, 10 cmH2O, 15 cmH2O, and 20 cmH2O. The presence of air leakage from the stapler stump at each pressure and the location of the leakage are evaluated. If air leakage occurs after evaluation, repair is performed and the procedure is terminated. After repair, only the presence of a persistent air leak should be checked. The duration of persistent air leak, duration of chest drain placement, and presence or absence of respiratory complications within 30 days after surgery will be checked and observation will be completed. |
|
|
|||
|
|||
|
術中ウォーターシーリングテストでのStaple断端からのエアリーク発生の有無 | Evaluation of air leakage from the staple line on Intraoperative water sealing test | |
|
(有効性評価項目)耐圧性、エアリーク持続時間、エアリーク発生部位、 (安全性評価項目)術後30日以内の呼吸器合併症発生、疾病等の発生、不具合の発生 |
(Efficacy endpoints) Pressure resistance, the duration of air leak, air leak location. (Safety endpoints) Occurrence of respiratory complications, illness, and malfunction within 30 days a fter surgery |
|
医療機器 | ||
---|---|---|---|
|
承認内 | ||
|
|
|
エシェロン エンドパス ステイプルライン リンフ ォースメント |
|
吸収性組織補強材 | ||
|
30300BZX00044000 | ||
|
|
||
|
|
なし |
---|
|
||
---|---|---|
|
実施計画の公表日 |
|
|
2022年05月10日 |
|
|
研究終了 |
Complete |
|
|
あり | |
---|---|---|
|
|
あり |
|
賠償責任、死亡・後遺障害に対する補償金 | |
|
なし |
|
ジョンソン・エンド・ジョンソン株式会社 | |
---|---|---|
|
なし | |
|
||
|
||
|
||
|
||
|
なし | |
|
||
|
なし | |
|
|
なし | |
---|---|---|
|
||
|
|
神戸大学臨床研究審査委員会 | Kobe University Clinical Research Ethical Committee |
---|---|---|
|
CRB5180009 | |
|
兵庫県神戸市中央区楠町7-5-2 | 7-5-2,Kusunoki cho,Chuo ku,Kobe City, Hyogo, Hyogo |
|
078-382-6669 | |
|
cerb@med.kobe-u.ac.jp | |
|
承認 |
|
|
---|---|
|
|
|
|
|
該当しない | |
---|---|---|---|
|
なし | none | |
|
なし | ||
|
該当しない | ||
|
該当しない | ||
|
該当しない |
|
|
---|---|
|
|
|
|
設定されていません |
---|---|
|
設定されていません |
|
研究計画書 1.2.pdf | |
---|---|---|
|
同意書 1.2.pdf | |
|
Attached sheet A.pdf |